Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Rev. bras. oftalmol ; 81: e0070, 2022. graf
Article in English | LILACS | ID: biblio-1407683

ABSTRACT

ABSTRACT Chlorpromazine is a medication widely used in psychiatry for the treatment of psychoses, especially schizophrenia. Since 1964, published articles have been correlating this medication with the appearance of ocular alterations. In this paper, we report the case of a 65-year-old patient with ocular effects due to long-term therapy with chlorpromazine. Biomicroscopy of both eyes presented diffuse granular brown deposits, most prominent at the deep stroma and corneal endothelium level. Also showed anterior subcapsular brown deposits with a stellate pattern in the lens. The total amount exceeds 2.000g (significant for the ocular alterations described) considering the patient's daily dosage of chlorpromazine of 300mg for ten years. After performing complete ophthalmic evaluation and discarding other causes for the ocular deposits, we diagnosed a secondary corneal deposit and cataract due to the use of chlorpromazine. This case reinforces the importance of periodic follow-up with an ophthalmologist for chlorpromazine users to trace ocular changes, heeding the exposure time and its dosage.


RESUMO A clorpromazina é uma medicação muito empregada na psiquiatria para tratamento de psicoses, especialmente em casos de esquizofrenia. Desde 1964 existem artigos publicados que correlacionam o uso dessa medicação com o aparecimento de alterações oculares. Neste trabalho, relatamos o caso de um paciente de 65 anos com efeitos oculares devido à terapia de longo prazo com clorpromazina. A biomicroscopia de ambos os olhos apresentou depósitos granulares difusos e de cor marrom, mais proeminente ao nível do estroma profundo e do endotélio da córnea, além de depósitos castanhos subcapsulares anteriores centrais em um padrão estrelado no cristalino. Considerando a dose diária de clorpromazina de 300mg por 10 anos usada pelo paciente, a quantidade total ultrapassa 2.000g (dose considerada significativa para as alterações oculares descritas). Após avaliação oftalmológica completa e descartado outras causas desses depósitos oculares, foram diagnosticados depósito corneano e catarata secundários ao uso de clorpromazina. O caso apresentado reforça a importância do acompanhamento oftalmolÓgico periÓdico de usuários de clorpromazina para o rastreio de alteraçÕes oculares, atentando-se ao tempo de exposição à droga e à posologia da mesma.


Subject(s)
Humans , Male , Aged , Cataract/chemically induced , Chlorpromazine/adverse effects , Chlorpromazine/toxicity , Cornea/drug effects , Corneal Diseases/chemically induced , Corneal Opacity/chemically induced , Pigmentation Disorders/chemically induced , Antipsychotic Agents/adverse effects , Antipsychotic Agents/toxicity , Antipsychotic Agents/therapeutic use , Bipolar Disorder/drug therapy , Visual Acuity , Chlorpromazine/administration & dosage , Chlorpromazine/therapeutic use , Corneal Diseases/diagnosis , Corneal Opacity/diagnosis , Slit Lamp , Slit Lamp Microscopy
2.
Rev. bras. oftalmol ; 75(5): 396-397, sept.-out. 2016. graf
Article in English | LILACS | ID: lil-798067

ABSTRACT

ABSTRACT We describe a six-year-old boy with a history of hematuria, posterior polymorphous corneal dystrophy and dots and fleck retinopathy. Alport syndrome should be ruled out in patients presenting with posterior polymorphous corneal dystrophy or anterior lenticonus and a family history of renal disease.


RESUMO Descrevemos um paciente de 6 anos de idade com história de hematúria, distrofia corneana polimorfa posterior e retinopatia em "dots and flecks". Síndrome de Alport deve ser excluída se o paciente apresentar com distrofia corneana polimorfa posterior ou lenticone anterior com historia familiar de doença renal.


Subject(s)
Humans , Male , Child , Retinal Diseases/etiology , Corneal Dystrophies, Hereditary/etiology , Nephritis, Hereditary/complications , Retinal Diseases/diagnosis , Corneal Dystrophies, Hereditary/diagnosis , Slit Lamp Microscopy , Nephritis, Hereditary/genetics
3.
Arq. bras. oftalmol ; 72(2): 189-193, mar.-abr. 2009. graf, tab
Article in English | LILACS | ID: lil-513887

ABSTRACT

Purpose: To evaluate the prediction of refraction using the SRK/T formula for intraocular lens (IOL) calculation in eyes with medium axial length after phacoemulsification. Methods: This prospective study enrolled 33 eyes with nuclear cataract that underwent phacoemulsification. All procedures were performed by one surgeon with theintraocular lens placed within the capsular bag. The same technician whowas unaware of the purpose of the study made all the measurements. Theachieved refractive error one month after surgery was compared to the predicted postoperative refractive error by the SRK/T formula. Results: The ocular axial length varied between 22.2 mm and 24.5 mm. The mean predicted refraction was -0.431 ± 0.181 D and the mean achieved postoperative spherical equivalent was -0.220 ± 0.732 D. Eighteen eyes (55%) had a refractive error between ± 0.50 D and thirty eyes (91%) between ± 1.00 D of the predicted refraction. There was a tendency toward hyperopic shift (mean ± SD: 0.211 ± 0.708 D, p=0.009). Conclusion: The SRK/T formula demonstrated a satisfactory accuracy to calculate the error of refraction in eyes with medium axial length.


Objetivo: Avaliar resultados refracionais utilizando a fórmula SRK/T no cálculo de lentes intraoculares (LIO) em olhos comcomprimento axial médio após facoemulsificação. Métodos: Este estudo prospectivo envolveu 33 olhos com catarata nuclear que foram submetidos a facoemulsificação. Todas as cirurgias foram realizadas pelo mesmo cirurgião com lentes intraoculares no saco capsular. O mesmo tecnólogo, o qualnão sabia o objetivo do estudo, realizou todas as medidas biométricas. O erro refracional atingido um mês após a cirurgia foi comparado ao erro refracional pós-operatório previsto pelafórmula SRK/T. Resultados: O comprimento axial variou entre 22,2 mm e 24,5 mm. A refração média prevista foi -0,431 ± 0,181 dioptrias (D) e o equivalente esférico pós-operatório alcançado foi -0,220 ± 0,732 D. Dezoito olhos (55%) obtiveram errorefracional de ± 0,50 D e 30 olhos (91%) entre ± 1,00 D da refração prevista. Houve tendência a um erro hipermetrópico (média±SD: 0,211 ± 0,708 D, p=0,009). Conclusão: A fórmula SRK/T demonstrou acurácia satisfatória no cálculo do erro refracional em olhos de comprimento axial médio.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Lens Implantation, Intraocular , Phacoemulsification/methods , Predictive Value of Tests , Prospective Studies , Refractometry , Reproducibility of Results , Treatment Outcome , Visual Acuity
4.
Arq. bras. oftalmol ; 71(5): 719-721, set.-out. 2008. ilus
Article in Portuguese | LILACS | ID: lil-497228

ABSTRACT

Relatamos dois casos de exfoliação verdadeira da cápsula, acontecendo em pacientes idosos sem história de exposição prolongada a altas temperaturas ou passado de inflamação intra-ocular. Os aspectos biomicroscópicos, anátomo-patológicos e possíveis implicações cirúrgicas são comentados.


We report two cases of true capsular exfoliation occurring in elderly patients with no known history of prolonged heat exposure or intraocular inflammation. The biomicroscopic aspects, histopathologic findings and possible surgical implications are discussed.


Subject(s)
Aged, 80 and over , Female , Humans , Male , Lens Capsule, Crystalline/pathology , Lens Diseases/diagnosis , Capsulorhexis , Lens Capsule, Crystalline/surgery , Lens Diseases/surgery , Phacoemulsification
SELECTION OF CITATIONS
SEARCH DETAIL